HVAC validation checklist: the tests your cleanroom needs before an audit

Airflow, air changes, HEPA integrity, particle counts and pressure differentials: what each test proves, and what auditors look for in the report.

17 Oct 2026

Cleanroom classification is only as strong as the HVAC evidence behind it. Before an inspection, make sure your validation package covers each of these tests, with raw data recorded on calibrated instruments.

1. Airflow velocity and volume

Measure air velocity at each terminal filter and calculate the supply air volume. This is the basis for every air-change calculation that follows.

2. Air changes per hour

Calculate air changes for every room from the measured supply volume and the room volume. Compare against the design and your acceptance criteria.

3. HEPA filter integrity

Challenge each terminal and in-line HEPA filter with an aerosol (PAO/DOP) and scan for leaks with a photometer. Document the upstream concentration and any repairs.

4. Non-viable particle count

Count particles at the defined locations to classify the room to ISO 14644-1 and EU GMP grade limits, at rest and in operation as required.

5. Differential pressure and airflow direction

Record room-to-room pressure differentials and confirm airflow moves from cleaner to less clean areas, including smoke-pattern visualisation where your SOPs require it.

6. Recovery

Show how quickly the room returns to its classified state after a particle challenge.

7. Temperature and humidity

Map temperature and relative humidity against the product and process requirements.

What auditors check in the report